ADT761 Automated Pressure
Calibrator
|
|
- Fully automated pressure calibrator with built-in pressure generator/
controller to 375 psi (25 bar)
- 0.02%FS accuracy
- Dual pressure
modules
- Portable (12 lb)
|
With a built-in high
performance electronic pump and precision pressure controller, the ADT761 series
automated pressure calibrator provides a turn-key solution for calibration of
gauges, transmitters, and switches both in the field and in the laboratory. In a
portable package, this little calibrator can automatically generate from 90%
vacuum to 375 psi (25 bar) pressure with 0.005%FS pressure control stability and
0.02%FS accuracy. To improve the calibrator accuracy, two pressure modules with
differing ranges are used. These are built-in and integrated with the internal
pump and controller. With optional external pressure modules (ADT160 series),
the ADT761 can measure pressures up to 10,000 psi (700 bar) with 0.025%FS
accuracy. In addition to the pressure generation, control, and measurement
capabilities, the ADT761 also features HART communication capability, supply 24V
loop power, and read the current or voltage produced by the pressure
transducers. The state of art ADT761 automated pressure calibrator brings
automated pressure calibration to the field.
|
Features
|
Pressure
Range
|
Pressure generated by
built-in pump and controlled automatically from 90% vacuum to 375 psi (25
bar)
Pressure measured with external pressure modules (ADT160 series) to
10,000 psi (700 bar)
|
Accuracy
|
0.02%FS Fully
temperature compensated
|
Control
Stability
|
0.005%FS
|
Automation and Test
Program
|
Fully Automated
pressure calibration
Task preset and auto run
Auto step
|
Easy to Use
|
User friendly interface
Intuitive icon driven menu structure
|
Sourcing and Measuring
electrical signals
|
Measure mA or V with
0.01% RD + 0.005%FS accuracy
Source 0 to 22mA current
24 VDC loop power
supply to pressure transmitter during test
Automatic switch test
|
Misuse
Protection
|
Up to 30V misuse
protection on any two sockets
|
Display
|
7" LCD color screen
(800 × 480)
|
Documenting and data
logging
|
Task management
capability
Internal memory stores 120 tasks
Download tasks and upload
results
|
Hart Communication
capability
|
Support HART
instrumentation
|
Rechargeable
battery
|
Rechargeable battery
with up to 8 hours operation between charges
|
Leak testing
|
Apply leak test to an
external pressure system to determine the magnitude of pressure variations due
to leaks
|
Pipeline
Protection
|
Special design the
pipeline layout to avoid possible blockage and leakage
|
Portable
|
Only 12 lb
|
Multi Lingual
Interface
|
English,
Chinese
|
NIST
Traceable
|
NIST traceable
calibration certificate included
|
Model
|
Pressure Range
|
Pressure Module 1
|
Pressure Module 2
|
Range
|
Accuracy
|
Range
|
Accuracy
|
ADT761-D
|
-0.95 to 1 bar
(-14 to 15
psi)
|
-25 to 25 mbar
(-10 to 10 in
H2O)
|
0.05%FS
|
-1 to 1 bar
(-15 to 15
psi)
|
0.02%FS
|
ADT761-L
|
-0.95 to 7 bar
(-14 to 100
psi)
|
-1 to 2.5 bar
(-15 to 35
psi)
|
0.02%FS
|
0 to 7 bar
(0 to 100
psi)
|
0.02%FS
|
ADT761-M
|
-0.90 to 25 bar
(-13 to 375
psi)
|
-1 to 2.5 bar
(-15 to 35
psi)
|
0.02%FS
|
0 to 25 bar
(0 to 375
psi)
|
0.02%FS
|
* ADT761 calibrators support ADT160 series
intelligent digital pressure modules that are available for gauge, vacuum and
absolute pressure from -15 psi to 10,000 psi (-1 bar to 700 bar). Accuracy from
0.025%FS includes operation over 14°F to 122°F (-10°C to 50°C), one year
stability and calibration uncertainty. For detailed specification refer to
ADT160 series pressure modules datasheet.
|
Electrical Measurement and Source Accuracy
|
|
Range
|
Resolution
|
Accuracy
|
Voltage Measurement
|
±30.0000V
|
0.1mV
|
±(0.01%RD + 0.005%FS)
|
Current Measurement
|
±30.0000mA
|
0.1uA
|
±(0.01%RD + 0.005%FS)
|
Current Source
|
0.000 to 22.000mA
|
1uA
|
±(0.02%RD + 0.01%FS)
|
On-off Measurement
|
If the switch has detective
Voltage, the range is from 3V to 24V
|
DC 24V output
|
24V ± 0.5V
|
Control
Stability
|
<0.005%FS
|
Pressure
Connections
|
0.156 inch (¥Õ4 mm) test
hose on calibrator
Two 1/4"NPT female hand-tight connectors on the external
pressure manifold (included)
|
External Pressure
Module Connection
|
External pressure
module connector
|
Electrical
Connection
|
0.156 inch (4mm) banana
sockets
|
Data Logger
|
Storage capacity: 120
files maximum
|
Display
|
7" LCD color screen
(800 × 400)
Display rate : 5 readings per second
|
Pressure
Units
|
Pa,
kPa, MPa, psi, bar, mbar, inH2O@4°C, mmH2O@4°C, inHg@0°C,
mmHg @0°C, kgf/cm2
|
Power
|
Battery: Rechargeable
Li-ion Polymer battery (included)
Li-Battery working time: ~8 hours
Recharge time: ~3 hours
External Power: 110/220V Power adapter (DC 27 V)
(Included)
|
Environmental
Specification
|
Operating temperature:
0 °C to 50 °C
Storage temperature: -20 °C to 60 °C
Humidity: < 90%,
non-condensing
|
European
Compliance
|
Operating temperature:
0 °C to 50 °C
Storage temperature: -20 °C to 60 °C
Humidity: < 90%,
non-condensing
|
European
Compliance
|
CE Marked
|
Communication
|
RS232 (DB9/F,
environmentally sealed)
Baud rate: 2400, 4800, 9600, 19200, 38400, 57600,
115200
Data length: 7 Bits, 8 Bits
Stop bit: 1 Bit, 2 Bits
Address:
from 1 to 121
|
Dimension
|
11.65" × 7.32" × 7.09"
(296mm × 186mm × 180mm)
|
Weight
|
12.4 lb (5.6
kg)
|
Warranty
|
18 months
|
|
|
Models and Accessories
|
|
Accessories (licluded)
|
ADT106-N or DT106-B
External Pressure Manifold
|
1 pc
|
9818 110V/220V external
Power adapter
|
1 pc
|
9722 Chargeable Li-ion
battery
|
1 pc
|
9022 Test Leads for
calibrator
|
2 sets(4 pc)
|
9020 Short circuit
cable
|
1 set(2 pc)2
|
9907 Carrying case for
ADT761 calibrator and accessory
|
1 pc
|
Optional Accessories
|
Model
Number
|
Description
|
ADT100-761-4N
|
Hose Test Kit, 5 feet
flexible hose, 0.156" (4mm) tube to 1/4NPT hand-tight quick connector
|
ADT100-761-4B
|
Hose Test Kit, 5 feet
flexible hose, 0.156" (4mm) tube to 1/4BSP hand-tight quick connector
|
ADT106-N
|
External Pressure
Manifold (with two 1/4NPT hand-tight quick connectors)
|
ADT106-B
|
External Pressure
Manifold (with two 1/4BSP hand-tight quick connectors)
|
ADT160
|