ADT761 Automated Pressure Calibrator
ÆǸŰ¡°Ý:
(ºÎ°¡¼¼ º°µµ)

Á¦Á¶»ç: ADDITEL
Á¦Ç°ÄÚµå: ADT761-M
¾Ð·Â¹üÀ§: -0.95 to 25 bar
Á¤È®µµ: 0.02 %ÀÇ FS
Ư±â»çÇ×1: ¾Ð·Â ¹ß»ý±â / ÄÁÆ®·Ñ·¯ 375 PSI (25 ¹Ù)¿¡ ³»Àå µÈ ÀüÀÚµ¿ ¾Ð·Â Ķ¸®ºê·¹ÀÌÅÍ
Ư±â»çÇ×2: ¿ÏÀü ÀÚµ¿ ¾Ð·Â º¸Á¤ ¹× ÀÛ¾÷ ¹Ì¸® ¼³Á¤ ÀÚµ¿ ½ÇÇà
¼Ò°³Çϱâ:
ÁÖ¹®¼ö·®:
°³

ADT761  Automated Pressure Calibrator

-  Fully automated pressure calibrator  with built-in pressure  generator/
   controller  to 375 psi (25 bar)
-  0.02%FS accuracy
-  Dual pressure modules
-  Portable (12 lb)

With a built-in high performance electronic pump and precision pressure controller, the ADT761 series automated pressure calibrator provides a turn-key solution for calibration of gauges, transmitters, and switches both in the field and in the laboratory. In a portable package, this little calibrator can automatically generate from 90% vacuum to 375 psi (25 bar) pressure with 0.005%FS pressure control stability and 0.02%FS accuracy. To improve the calibrator accuracy, two pressure modules with differing ranges are used. These are built-in and integrated with the internal pump and controller.  With optional external pressure modules (ADT160 series), the ADT761 can measure pressures up to 10,000 psi (700 bar) with 0.025%FS accuracy. In addition to the pressure generation, control, and measurement capabilities, the ADT761 also features HART communication capability, supply 24V loop power, and read the current or voltage produced by the pressure transducers. The state of art ADT761 automated pressure calibrator brings automated pressure calibration to the field.

 

  Features

Pressure Range

Pressure generated by built-in pump and controlled automatically from 90% vacuum to 375 psi (25 bar)
Pressure measured with external pressure modules (ADT160 series) to 10,000 psi (700 bar)

Accuracy

0.02%FS  Fully temperature compensated

Control Stability

0.005%FS

Automation and Test Program

Fully Automated pressure calibration
Task preset and auto run
Auto step

Easy to Use

User friendly interface
Intuitive icon driven menu structure

Sourcing and Measuring electrical signals

Measure mA or V with 0.01% RD + 0.005%FS accuracy
Source 0 to 22mA current 
24 VDC loop power supply to pressure transmitter during test
Automatic switch test

Misuse Protection

Up to 30V misuse protection on any two sockets

Display

7" LCD color screen (800 × 480)

Documenting and data logging

Task management capability
Internal memory stores 120 tasks
Download tasks and upload results

Hart Communication capability

Support HART instrumentation

Rechargeable battery

Rechargeable battery with up to 8 hours operation between charges

Leak testing

Apply leak test to an external pressure system to determine the magnitude of pressure variations due to leaks

Pipeline Protection

Special design the pipeline layout to avoid possible blockage and leakage

Portable

Only 12 lb

Multi Lingual Interface

English, Chinese

NIST Traceable 

NIST traceable calibration certificate included

 

  Specifications

 Pressure Ranges

Model

Pressure Range

Pressure Module 1

Pressure Module 2

Range

Accuracy

Range

Accuracy

ADT761-D

-0.95 to 1 bar
(-14 to 15 psi)

-25 to 25 mbar
(-10 to 10 in H2O)

0.05%FS

-1 to 1 bar
(-15 to 15 psi)

0.02%FS

ADT761-L

-0.95 to 7 bar
(-14 to 100 psi)

-1 to 2.5 bar
(-15 to 35 psi)

0.02%FS

0 to 7 bar
(0 to 100 psi)

0.02%FS

ADT761-M

-0.90 to 25 bar
(-13 to 375 psi)

-1 to 2.5 bar
(-15 to 35 psi)

0.02%FS

0 to 25 bar
(0 to 375 psi)

0.02%FS

* ADT761 calibrators support ADT160 series intelligent digital pressure modules that are available for gauge, vacuum and absolute pressure from -15 psi to 10,000 psi (-1 bar to 700 bar). Accuracy from 0.025%FS includes operation over 14°F to 122°F (-10°C to 50°C), one year stability and calibration uncertainty. For detailed specification refer to ADT160 series pressure modules datasheet.


 Electrical Measurement and Source Accuracy

 

Range

Resolution

Accuracy

Voltage Measurement

±30.0000V

0.1mV

±(0.01%RD + 0.005%FS)

Current Measurement

±30.0000mA

0.1uA

±(0.01%RD + 0.005%FS)

Current Source

0.000 to 22.000mA

1uA

±(0.02%RD + 0.01%FS)

On-off Measurement

If the switch has detective Voltage, the range is from 3V to 24V

DC 24V output

24V ± 0.5V


Control Stability

<0.005%FS

Pressure Connections

0.156 inch (¥Õ4 mm) test hose on calibrator
Two 1/4"NPT female hand-tight connectors on the external pressure manifold (included)

External Pressure Module Connection

External pressure module connector

Electrical Connection

0.156 inch (4mm) banana sockets

Data Logger

Storage capacity: 120 files maximum

Display

7" LCD color screen (800 × 400)
Display rate : 5 readings per second

Pressure Units

Pa, kPa, MPa, psi, bar, mbar, inH2O@4°C, mmH2O@4°C, inHg@0°C, mmHg @0°C, kgf/cm2

Power

Battery: Rechargeable Li-ion Polymer battery (included)
Li-Battery working time: ~8 hours
Recharge time: ~3 hours
External Power: 110/220V Power adapter (DC 27 V) (Included)

Environmental Specification

Operating temperature: 0 °C to 50 °C
Storage temperature: -20 °C to 60 °C
Humidity: < 90%, non-condensing

European Compliance

Operating temperature: 0 °C to 50 °C
Storage temperature: -20 °C to 60 °C
Humidity: < 90%, non-condensing

European Compliance

 CE Marked

Communication

RS232 (DB9/F, environmentally sealed)
Baud rate: 2400, 4800, 9600, 19200, 38400, 57600, 115200
Data length: 7 Bits, 8 Bits
Stop bit: 1 Bit, 2 Bits
Address: from 1 to 121

Dimension

11.65" × 7.32" × 7.09" (296mm × 186mm × 180mm)

Weight

12.4 lb (5.6 kg)

Warranty

18 months

   

 

 
 

Models and Accessories

 

 Accessories (licluded)

ADT106-N or DT106-B External Pressure Manifold

1 pc

9818 110V/220V external Power adapter

1 pc

9722 Chargeable Li-ion battery

1 pc

9022 Test Leads for calibrator

2 sets(4 pc)

9020 Short circuit cable

1 set(2 pc)2

9907 Carrying case for ADT761 calibrator and accessory

1 pc

Optional Accessories

Model Number

Description

ADT100-761-4N

Hose Test Kit, 5 feet flexible hose, 0.156" (4mm) tube to 1/4NPT hand-tight quick connector

ADT100-761-4B

Hose Test Kit, 5 feet flexible hose, 0.156" (4mm) tube to 1/4BSP hand-tight quick connector

ADT106-N

External Pressure Manifold (with two 1/4NPT hand-tight quick connectors)